LANDU / APPLICATION SOLUTIONS

Waterproof Mortar Solutions Built Around Your Application

High-performance additive solutions for waterproof mortar, supporting water repellency, adhesion, workability and crack-control evaluation across a wide range of construction applications.

Waterproof mortar application on a construction substrate
Water RepellencyReduce capillary water uptake
Bond & FlexibilitySupport adhesion and deformability
WorkabilityWater retention and application control
Crack ControlSupport microcrack management
01 / APPLICATIONS

Choose Your Application

Explore common waterproof mortar applications, identify the main formulation challenges and shortlist suitable additive families.

Bathroom floor waterproofing during construction

Wet-Area Waterproofing

Bathrooms, kitchens, balconies and terraces where substrate bonding and moisture exposure must be considered together.

Explore materials →
Construction workers applying cementitious coating to an exterior wall; Unsplash License

Exterior Wall Protection

Exterior renders and protective mortar where rain exposure, vertical application and crack risk require evaluation.

Explore materials →
Empty tiled swimming pool, water-retaining structure; Unsplash License

Water Tanks & Swimming Pools

For water-retaining structures, confirm immersion suitability and the performance of the complete waterproofing system.

Explore materials →
Application boundary: Negative-side water pressure, permanent immersion, tunnels and movement joints require system-level design and qualification. An additive or ordinary waterproof mortar alone does not establish suitability for every exposure condition.
02 / ADDITIVE SOLUTIONS

Match Additives to the Performance You Need

Shortlist LANDU materials by their role in the formulation, then confirm grade suitability through current technical documents and complete-mortar trials.

LANDU redispersible polymer powder product
ACCURATE™ / POLYMER MODIFICATION

Redispersible Polymer Powder

8032H / 8035H / 8048H

Polymer modification for adhesion, flexibility and durability in compatible cementitious mortar systems.

NOVASTAR silicone hydrophobic powder
NOVASTAR™ / WATER REPELLENT

Silicone Hydrophobic Powder

SHP75 / SHP80

Hydrophobic modification to help reduce capillary water uptake in suitable cement-based dry-mix formulations.

NOVASTAR powder defoamer product
NOVASTAR™ / AIR CONTROL

Powder Defoamer

P805 / P806 / P807

Controls unwanted entrained air in dry-mix mortar. Grade selection depends on system conditions and trial results.

LANDERCOLL HPMC cellulose ether product
LANDERCOLL® / CELLULOSE ETHER

HPMC / HEMC (MHEC)

K40 / K100 / K100HT · EM40 / EM100 / EM100HT

Water retention, fresh-mortar consistency and workability. Select the grade by viscosity and the target application.

SUPPORTING MATERIALS
NOVASTAR hydroxypropyl starch ether product
HPSSupplementary rheology and anti-sag adjustment.
NOVASTAR polypropylene fiber product
PP FiberOptional micro-reinforcement for crack-control evaluation.
NOVASTAR PCE superplasticizer powder
PCEOptional water-reduction aid where binder compatibility supports its use.
Need to optimize water demand or flow?

PCE should be selected by binder chemistry and evaluated with the cellulose ether, RDP and other admixtures in the complete formulation.

Explore NOVASTAR™ PCE →
03 / FORMULATION PATHWAY

Build the Additive Package Around the Target Performance

Cellulose EtherWater retention & workability
RDPAdhesion & flexibility
SHPHydrophobic modification
DefoamerAir control & compactness
PCE (If Required)Water reduction & flow
04 / PERFORMANCE EVALUATION

Match Additives to Performance Targets

Use this matrix as a preliminary material-screening guide. The finished mortar must be evaluated as a complete system.

Performance TargetPrimary AdditiveSupporting Additive
Reduced capillary water absorptionSHP75 / SHP80RDP
Bond strengthRDPHPMC / HEMC
Water retention & workabilityHPMC / HEMCHPS
Air controlP805 / P806 / P807—
Microcrack controlPP Fiber (optional)RDP
05 / TECHNICAL STANDARDS & RESOURCES

Reference Standards & Technical Materials

Confirm the applicable standard according to the waterproof mortar type, market and project specification.

READY-MIXED MORTAR
GB/T 25181-2019

Ready-mixed mortar. Check the relevant provisions for ordinary dry-mix waterproof mortar.

POLYMER-MODIFIED CEMENT MORTAR
JC/T 984-2011

Polymer modified cement mortar for waterproofing. Confirm the applicable product type and test requirements.

Standards define finished-product requirements and test methods; they are not performance certificates for an individual additive. Verify the current standard edition and project-specific requirements before qualification.
06 / TECHNICAL EVALUATION

Validate the Complete Waterproof Mortar Formulation

Product selection should be followed by controlled testing with the actual binder, fillers, water ratio and additive package.

LANDU application laboratory
LANDU / APPLICATION LABORATORY

Formulation Screening

Compare candidate grades and additive combinations under matched preparation and curing conditions.

WorkabilityWater retentionCompatibility
LANDU material evaluation equipment
TESTING / PERFORMANCE REVIEW

Performance Verification

Define the required test methods for water absorption, bond retention, cracking and hardened-mortar performance.

Water absorptionBond strengthCrack assessment
Testing equipment shown is part of LANDU's published laboratory / testing media. The images do not represent a waterproof-mortar test result or certify any specific grade.
07 / FAQ

Technical Questions Before Grade Selection

Practical points for waterproof mortar manufacturers, formulation engineers and technical buyers.

Ask LANDU Technical Team →

Build Your Waterproof Mortar Formulation with LANDU

Tell us about your application, binder system and performance requirements. LANDU can support additive selection, technical documentation and sample evaluation for your formulation trials.

LANDU supplies functional raw materials for customer-developed formulations. Final performance depends on the complete system and must be verified under the intended application conditions.