RDP for Putty: How to Select the Right Tg Range by Putty Type
Answer: Selecting the right redispersible polymer powder (RDP) for putty starts with one number: the glass transition temperature (Tg). Formulators often see technical datasheets recommending "low Tg for insulation systems" or "higher Tg for applications requiring greater hardness" without a clear explanation of what those ranges mean in practice or how the values are determined. This article breaks down the selection logic: which Tg range fits each putty type, and which testing standard is used to determine the Tg value reported on the datasheet.
1. Tg Is the First Parameter Because It Quantifies Flexibility
Tg is the temperature at which a polymer transitions from a hard, glassy state to a soft, rubbery state. For RDP in a putty formulation, this influences the flexibility and rigidity of the polymer film at ambient temperature: a lower Tg generally means a softer, more flexible polymer film, helping the putty accommodate minor substrate movement. A higher Tg generally means a harder, more rigid film, which may be beneficial when greater surface hardness is required.
This is why Tg is more useful than vague descriptors like "high flexibility" or "medium flexibility" on a product page. It is a measurable, comparable parameter listed in technical data sheets (TDS), allowing formulators to compare different RDP grades. The practical relationship is straightforward: higher Tg generally indicates greater rigidity, while lower Tg generally indicates better flexibility.
2. Matching Tg Range to Putty Type
The table below summarizes the selection direction for three common putty categories.
| Putty Type | Recommended Tg Range | Selection Logic |
|---|---|---|
| Insulation system putty / Exterior elastic putty | -5°C or lower | Must accommodate thermal and hygric movement of the insulation board; flexibility is the priority |
| Standard interior wall putty | Around 5°C | Balances adhesion, workability, and moderate flexibility |
| Interior water-resistant putty / Exterior putty emphasizing water resistance | 10°C to 15°C | Higher rigidity supports hardness and water resistance; flexibility requirement is relaxed |
Product data supports this selection approach. An EVA-based RDP with a Tg of -5°C is classified as "high flexibility" and recommended for insulation plaster and exterior elastic wall putty. A Tg of 5°C corresponds to "medium" or "neutral" flexibility, with recommended applications including interior wall putty. At the higher end, a Tg of 10°C is listed for interior water-resistant putty, while a Tg of 15°C carries a "low flexibility" rating and is recommended for exterior water-resistant plaster. These examples illustrate how different RDP grades are positioned for different putty applications.
For insulation systems specifically, flexibility is critical because the putty layer forms part of a multi-layer system involving the insulation board and finish coating. An RDP with insufficient flexibility may not adequately accommodate dimensional changes in EPS or XPS boards, potentially contributing to cracking or delamination. This is why low-Tg grades are generally the starting point when selecting RDP for insulation system putty.For more details on the role of additives in different wall putty applications, explore our application guide.
Tg is a directional indicator, not the only variable in RDP selection. RDP dosage (typically in the range of 1% to 1.5% of the total dry formulation, depending on the application and formulation) and the ratio of cementitious binder to filler also significantly affect the final flexibility and crack resistance. The Tg range helps narrow down suitable candidates, but final confirmation should come from testing the selected RDP in the actual putty formulation.
3. What Standard Is Behind the Tg Number?
Tg is not a standard itself; it is a physical parameter. The numerical value on a supplier's datasheet is obtained by a specific test method.
The core method standard is GB/T 19466.2 (Plastics — Differential scanning calorimetry — Part 2: Determination of glass transition temperature), which corresponds to ISO 11357-2. The test uses Differential Scanning Calorimetry (DSC) to measure heat flow changes as the polymer is heated through its transition region. The RDP product standard GB/T 29594-2013 lists Tg as a technical indicator and references this DSC method for determination.
The RDP product standard GB/T 29594-2013 also lists Tg as a technical indicator. Its original Clause 6.8 references the earlier test method, GB/T 19466.2-2004, which was superseded by the 2025 edition on July 1, 2026.
When comparing RDP grades from different suppliers, check not only whether DSC was used, but also whether the test conditions and Tg determination method are consistent. This provides a more meaningful basis for comparing reported Tg values across different products.
4. What to Check Beyond Tg
Tg sets the direction, but three other factors determine whether the selected grade performs as expected in a putty formulation.
Dosage. RDP dosage directly affects the polymer content in the finished putty and its overall performance. For both interior and exterior wall putty, a dosage of 1.0% to 1.5% can be used as a reference range, with the final level adjusted according to the formulation and performance requirements. A low-Tg grade used at insufficient dosage will not necessarily deliver the expected flexibility.
Binder-to-filler ratio. A formulation with a high proportion of cementitious binder or gypsum and insufficient RDP may exhibit limited flexibility, even when a low-Tg grade is used. The balance between the inorganic matrix and polymer content therefore needs to be adjusted according to the target deformation capacity and application requirements.Besides RDP, cellulose ethers also contribute to putty formulation performance. Learn more about the roles of HPMC and RDP in wall putty formulations.
Actual crack resistance testing. The most direct verification is to evaluate the finished putty's crack resistance and deformation capacity under relevant application conditions, rather than relying solely on the Tg value reported on the RDP datasheet. A grade with a suitable Tg can still underperform if the dosage, formulation balance, or curing conditions are not properly optimized.
The working rule: select the Tg direction according to the putty type, optimize the RDP dosage and binder-to-filler balance in the target formulation, and confirm the result through practical crack-resistance testing. Tg narrows the search; formulation testing makes the final decision.
5. Frequently Asked Questions
What is the recommended Tg for RDP used in wall putty?
The recommended Tg depends on the putty type and its flexibility requirements. Low-Tg grades, such as -5°C or lower, are generally suitable starting points for insulation system putty and exterior elastic putty. Around 5°C may suit standard interior putty, while grades in the 10°C to 15°C range may be considered for applications requiring greater surface hardness. The final choice should be verified through formulation testing.
Is a lower Tg always better for wall putty?
No. A lower Tg generally provides greater polymer film flexibility, which can be beneficial for applications exposed to substrate movement or deformation. However, standard interior putty or applications requiring greater surface hardness may not need the lowest-Tg grade. The appropriate Tg depends on the balance between flexibility, rigidity, and other performance requirements.
How much RDP should be added to wall putty?
A dosage of 1.0% to 1.5% of the total dry formulation can be used as a reference range for both interior and exterior wall putty. The actual dosage depends on the RDP grade, binder-to-filler ratio, and required performance. Laboratory trials are necessary to determine the appropriate level for each formulation.
Does a higher Tg RDP provide better water resistance?
Not necessarily. A higher Tg generally indicates a harder and more rigid polymer film, but it does not directly determine the water resistance of the finished putty. Water resistance also depends on the polymer's chemical properties, polymer content, binder system, and overall formulation.
How can I verify whether an RDP grade is suitable for my putty formulation?
Start by comparing the RDP's Tg and other relevant technical data, then evaluate the grade in the target formulation. Adjust the RDP dosage and binder-to-filler ratio as needed, and assess the finished putty's adhesion, flexibility, and crack resistance under relevant application conditions. Actual formulation testing is more reliable than selecting a grade based on Tg alone.
Discuss Your Wall Putty Formulation with LANDU
LANDU supplies functional raw materials and additive grades for wall putty manufacturers. Share your binder system, target flow and current formulation challenge and required product information so the team can discuss suitable additive candidates and sample evaluation.